Wire Gauge for Micro Linear Actuators

Selecting wire for a micro linear actuator is not a space-saving compromise or a matter of picking whatever cable fits the connector. It is an electrical delivery calculation.

Small actuators often operate in tight enclosures where routing a thick harness is difficult. Thin wire reduces the space required for routing, but its higher resistance produces a larger voltage drop as motor current increases under load. If line voltage drops too far before reaching the terminal pins, speed degrades, peak force drops, and onboard control electronics can reset.

Choosing the right wire gauge requires balancing allowable voltage drop across the complete round-trip circuit against the physical space available in the enclosure.

The Mechanism of Voltage Loss

American Wire Gauge (AWG) is a standardized system for specifying conductor size. As the AWG number increases, the conductor becomes smaller and its resistance per unit length increases.


Resistance restricts current flow and creates a voltage drop between the power source and the load. That relationship follows Ohm's law:

Voltage Drop = Current × Resistance

In DC motor circuits, resistance applies to the full current loop. Current flows out through the supply conductor and returns through the return conductor. If an actuator sits 3 meters from its power supply, the current travels through 6 meters of wire. Ignoring the return leg cuts the calculated resistance in half, hiding potential voltage delivery problems before the system is built.


Wire Gauge (AWG) Linear Resistance Total Resistance (6 m loop) Voltage Drop at 1 A Voltage Drop at 6 V (%)
20 AWG~0.033 Ω/m0.20 Ω0.20 V3.30%
22 AWG~0.053 Ω/m0.32 Ω0.32 V5.30%
24 AWG~0.084 Ω/m0.50 Ω0.50 V8.30%
26 AWG~0.134 Ω/m0.80 Ω0.80 V13.30%
28 AWG~0.213 Ω/m1.28 Ω1.28 V21.30%

Table: Conductor resistance and voltage drop across a 6 m total loop length at 1 A draw.

Why Micro Actuators Are Sensitive to Line Loss

Industrial linear actuators often run on 24 V or higher, where losing 1 V across a cable run represents less than a 5% drop. Micro actuators typically operate at lower supply levels, such as 6 V or 12 V.


At 6 V, that same 1 V loss drops 16.7% of the total voltage.


As mechanical load increases, a DC actuator typically draws more current. Higher current produces a larger voltage drop across the same wiring resistance, so voltage delivery should be checked under the expected load rather than only under no-load conditions.

Related Article: Preventing Overload in Micro Linear Actuator Systems

Calculating for Load Current, Not Idle Ratings

Current draw changes with mechanical load and varies by actuator model, voltage, and gear ratio. Actuonix datasheets show how current changes as actuator force increases, so check the current curve and published specifications for the exact actuator being used. The published stall current provides a useful worst-case maximum-current reference.


If several actuators can operate at the same time from the same power supply, their current requirements need to be considered together. Actuonix recommends summing the stall currents of the actuators that may operate simultaneously when determining the maximum current requirement.

Related Article: How to Choose a Power Supply for a Micro Linear Actuator

Selecting the Wire Gauge

Start with the Actuonix datasheets for the exact actuator model to confirm nominal supply voltage and peak current draw. Measure the full harness routing distance from power supply to actuator, then double it to account for the supply and return conductors. Calculate total wire resistance and multiply by peak current to verify that terminal voltage stays within specification under full load.

If the calculated voltage drop is significant for the application, use a larger conductor or shorten the cable run to reduce the voltage lost in the wiring.

Check the Electrical Requirements for Your Actuator

Before selecting wire size, confirm the rated voltage and current requirements for the exact actuator model. Use the Actuonix Actuator Comparison Chart to compare actuator options, then check the model datasheet for its detailed electrical specifications. You can also contact us and our team can help you review the requirements.

Frequently Asked Questions

Do Actuonix stepper actuators use the same current calculation as DC actuators?

No. Actuonix stepper models such as the P8-ST and S20 specify maximum current per phase rather than DC-motor stall current. Their wiring and power requirements should therefore be evaluated together with the stepper driver.

Can I extend the actuator cable?

Yes, but additional cable length adds conductor resistance and therefore increases voltage drop. Actuonix offers model-specific extension cables, including 26 AWG options for several actuator families. For custom extensions, cable length and actuator current should be considered rather than assuming the same wire size is suitable for every installation.

Does the same wire gauge work for every Actuonix actuator?

No. Different Actuonix models have different current requirements. For example, published stall current ranges from a few hundred milliamps on smaller models to 1 A on models such as the P16 and T16. Because voltage drop increases with current, the same wire length and gauge will not produce the same voltage drop for every actuator.